Lesson 2 of 15 · 15 min
Cell → pack → rack → container
- Calculate series/parallel
Cells in series raise voltage; in parallel raise capacity. 3.2 V LFP cells × 16 = 51.2 V module. Modules in series form a rack at ~700–1,500 V DC. Racks in parallel form a container.
India note
India example: A 20-ft container with 280 Ah cells: 416S × 10 racks ≈ 3.7 MWh.
Formula
kWh = V × Ah ÷ 1000
Worked example
51.2 V × 280 Ah = 14.3 kWh
Key takeaways
- Series = voltage
- Parallel = capacity
- Rack voltage matches PCS window